Savings that is reached by using this system - Helsinge Cent

Helsinge Central Heating Plant:

The Central Heating plant in the town Helsinge had the system installed in the autumn of 1997 as the first plant in Denmark. (This plant’s account year is = normal calendar year)

The total pipe loss before the system was install was calculated over a average of 3 years to a total of 10.486 MWh.

After the system was install the total pipe loss was calculated over a average of 4 years to a total of8.823 MWh.

The average savings pr./year was 1663MWh. = 10.486 MWh. - 8.823 MWh. at a prd. cost of 290DKR/Mwh.

When the production cost pr./MWh is 290 Dk.kr. then the savings was:
482.270 kr./pr.år = 1663 x 290 kr.

The total savings achieved over a 4 year period:

1.929.080 DKR. = 482.270 x 4

Tabel 1. The table for the last 3 years before the system was install.
Information
95 96 97 sum sum/3
Heatproduction
38.584 MWh
43.396 MWh
40.441 MWh
122.421 MWh
40.807 MWh
Heat sale
28.750 MWh
32.302 MWh
29.912 MWh
90.964 MWh
30.321 MWh
Pipeloss
9.834 MWh
11.094 MWh
10.529 MWh
31.457 MWh
10.486 MWh
Number of consumer
1059
1061
1063
|-|
|-|
Connected m³
571 m³
574 m³
576 m³
|-|
|-|


Table 2. The last 4 years with the system was install.
Information
98 99 00 01 sum sum/3
Heatproduction
38.962 MWh
37.239 MWh
36.154 MWh
38.562 MWh
150.917 MWh
37.729 MWh
Heatsale
28.271 MWh
28.681 MWh
27.214 MWh
28.922 MWh
113.088 MWh
28.272 MWh
Pipeloss
9.118 MWh
7.572 MWh
8.963 MWh
9.640 MWh
35.293 MWh
8.823 MWh

Connected consumers

1070
1074
1130
1152
|-|
|-|
Connected m³
577 m³
579 m³
595 m³
616 m³
|-|
|-|


Approximate savings on the emission of CO² pollution.

Average savings on heat production
3078 MWh. = 40807 MWh - 37739 MWh.

According to data from the emissiontabel naturalgas has a emssion of CO² of 57 kg pr. GJ when it is converted to heat.

1 MWh. = 3.6 GJ.

Savings pr. Year on CO² pollution; 341.248 Kg. = (1663 x 3.6) x 57 Kg.
The total savings over the last 4 years; 1.364.992 Kg. = 341.248 Kg. x 4